The humidex (short for humidity index) is an index number used by Canadian meteorologists to describe how hot the weather feels to the average person, by combining the effect of heat and humidity. The term humidex was coined in 1965.[1] The humidex is a nominally dimensionless quantity (though generally recognized by the public as equivalent to the degree Celsius) based on the dew point.

Plot of humidex depending on temperature and relative humidity

Range of humidex: Scale of comfort:[2][3]

  • 20 to 29: Little to no discomfort
  • 30 to 39: Some discomfort
  • 40 to 45: Great discomfort; avoid exertion
  • Above 45: Dangerous; heat stroke quite possible

History

The current formula for determining the humidex was developed by J. M. Masterton and F. A. Richardson of Canada's Atmospheric Environment Service in 1979. Humidex differs from the heat index used in the United States in being derived from the dew point rather than the relative humidity, though both dew point and relative humidity (when used in conjunction with air temperature) are directly related to atmospheric moisture.

For a long time, the record humidex in Canada was set by Windsor, Ontario, which hit 52.1 on 20 June 1953, as reported by Environment Canada.[4]

This value was beaten on 25 July 2007 when Carman, Manitoba, hit 52.6.[5][6]

Computation formula

When the temperature is 30 °C (86 °F) and the dew point is 15 °C (59 °F), the humidex is 34. If the temperature remains 30 °C (86 °F) and the dew point rises to 25 °C (77 °F), the humidex rises to 42. The humidex is higher than the U.S. heat index at equal temperature and relative humidity.

The humidex formula is as follows:[7][8]

where

  • H denotes the Humidex
  • Tair is the air temperature in °C
  • Tdew is the dewpoint temperature in °C
  • exp is the exponential function.

5417.7530 is a rounded constant based on the molecular weight of water, latent heat of evaporation, and the universal gas constant. The humidity adjustment approximately amounts to one Fahrenheit degree for every millibar by which the partial pressure of water in the atmosphere exceeds 10 millibars (10 hPa).

At the time the humidex was originally developed in 1965, Canada was still on the Fahrenheit scale, and thus the humidex was originally based on that. The 1979 reformulation, which added the 0.5555 factor (from the relation 1 °F = 5/9 °C), was largely to address metrication in Canada as the country switched to the Celsius scale.

Table

Humidex for range 15–43 °C
 Temperature (°C)
1516171819202122232425262728293031323334353637383940414243
Dew
point
(°C)
101617181920212223242526272829303132333435363738394041424344
111718192021222324252627282930313233343536373839404142434445
121718192021222324252627282930313233343536373839404142434445
131819202122232425262728293031323334353637383940414243444546
141819202122232425262728293031323334353637383940414243444546
151920212223242526272829303132333435363738394041424344454647
1621222324252627282930313233343536373839404142434445464748
17222324252627282930313233343536373839404142434445464748
182425262728293031323334353637383940414243444546474849
1926272829303132333435363738394041424344454647484950
20282930313233343536373839404142434445464748495051
212930313233343536373839404142434445464748495051
2231323334353637383940414243444546474849505152
23333435363738394041424344454647484950515253
243536373839404142434445464748495051525354
2537383940414243444546474849505152535455
26394041424344454647484950515253545556
274243444546474849505152535455565758
2844454647484950515253545556575859

See also

References