Предлошка:Инфокутија Електрана

Икона за документација Документација за предлошка[преглед] [уреди] [историја] [превчитај]

Употреба

Полна синтакса

Параметри

ПараметарОпис
Lead section: For all infoboxes
nameName of power station
official_nameOfficial name, if different from name. Preferably in native language.
imageImage filename, without File: parameter.

Animated (.gif) and media files (.ogv) are allowed, although browsers such as IE are unable to play this type of file; avoid using.

image_sizeAvoid using: Overrides the default 250px
image_altAlternative text for images.
image_captionCaption beneath image
location_mapName of a ПолКарта file. The coordinates must be specified as well (see below).
location_map_widthAvoid using: Overrides the default 250px
location_map_textCaption beneath the location map
lat_dLatitude degrees.
lat_mLatitude minutes. Omit or leave blank if lat_d is in decimal format.
lat_sLatitude seconds. Omit or leave blank if lat_d is in decimal format. Remember to avoid being overly precise.
lat_NSNorthern or Southern latitude (enter N or S). Omit or leave blank if lat_d is in decimal format.
long_dLongitude degrees.
long_mLongitude minutes. Omit or leave blank if long_d is in decimal format.
long_sLongitude seconds. Omit or leave blank if long_d is in decimal format. Remember to avoid being overly precise.
long_EWLongitude East or West (enter E or W). Omit or leave blank if long_d is in decimal format.
coordinates_typeOptional parameter to add additional coordinate functions. See here for more details.
coordinates_displayDisplay the coordinates inline or title, or both as inline,title.
coordinates_refUse this field to add references to the coordinates.
countryCountry where the facility is located. Do not use flag icons, as this places an unnecessary emphasis on nationality; see MOS:FLAG for a detailed rationale.
locationGeneral area where located. Avoid being overly-detailed.
statusState of the project. Enter any one of the following auto-expanding fields:

P=Proposed, U=Under construction, O=Operational, M=Mothballed, D=Decommissioned.

construction_beganDate construction of the first unit began, consider using {{Start date}}.
commissionedDate commissioned, or to be commissioned, of the first unit. Consider using {{Start date}}.
licence_expiresDate licence for the last unit expires.
decommissionedDate decommissioned, or to be decommissioned, of the last unit. Consider using {{End date}}.
costTotal cost of development
ownerOwner(s) of the power station. Consider limiting to the top two, and include ownership percentage.

Example: Owner1: 60% <br/>Owner2: 40%

operatorPlant operator(s). If different from owner.
developerPlant developer(s). If different from owner.
constructorBuilding/contracting companies.
Geothermal Power Stations
geothermal_typeThe type of geothermal power station. Enter any one of the following auto-expanding fields:

DS=Dry steam, FS=Flash steam, BC=Binary cycle.

geothermal_wellsNumber of geothermal wells.
max_well_depthDepth of the deepest well.
temp_requirementMinimum temperature requirement of geothermal source. Consider using: {{Convert|XX|C|F|0|abbr=on}}
thermal_power_geoMWt capacity.
cogeneration_geoIs the power station a cogeneration type? Add Yes or No.
geo_turbine_mwNumber of generators (turbines), and its corresponding gross megawatt capacity.

Example: 10 × 250 MW. For multiple generator capacities, use the <br/> function.

turbine_manu_geoManufacturers/suppliers of turbine(s)
Hydroelectric Power Stations (Pumped-storage)
upper_reservoirName of upper reservoir.
upper_res_capacityWater storage capacity of upper reservoir.
upper_res_ac_capacityActive storage capacity of upper reservoir, e.g. The amount of water from the reservoir's total storage that can be used for pumped-storage.
upper_res_elevationThe upper reservoir's elevation at normal storage level.
upper_res_catchmentCatchment area of upper reservoir.
upper_res_areaSurface area of upper reservoir.
upper_res_depthAverage water depth of upper reservoir.
lower_reservoirName of lower reservoir.
lower_res_capacityWater capacity of lower reservoir.
lower_res_ac_capacityActive storage capacity of lower reservoir, e.g. The amount of water from the reservoir's total storage that can be used for pumped-storage.
lower_res_elevationThe lower reservoir's elevation at normal storage level.
lower_res_catchmentCatchment area of lower reservoir.
lower_res_areaSurface area of lower reservoir.
lower_res_depthAverage water depth of lower reservoir.
penstocksNumber of penstocks from the upper reservoir to the power station.
pump_gen_unitsNumber of units used for both generating and pumping.

If these units are not used together, use the two parameters immediately below.

ps_gen_unitsNumber of generation units of the pumped-storage power station, if pump_gen_units don't apply.
turbine_manu_pspManufacturers/suppliers of turbine(s)
pumping_unitsNumber of pumping units to the upper reservoir, if pump_gen_units don't apply.
hydraulic_headHydraulic head from upper reservoir.
annual_pump_consumAmount of electricity consumed by pumping annually.
Nuclear Power Stations
reactors_operate_mwNumber of reactors operational, and its corresponding gross megawatte capacity.

Example: 12 × 600 MW. For multiple reactors capacities, use the <br/> function.

reactors_const_mwNumber of reactors under construction, and its corresponding future gross megawatte capacity.

Example: 12 × 600 MW. For multiple reactors capacities, use the <br/> function.

reactors_planned_mwNumber of reactors planned, and its corresponding future gross megawatte capacity.

Example: 12 × 600 MW. For multiple reactors capacities, use the <br/> function.

reactors_decom_mwNumber of reactors decommissioned, and its corresponding gross megawatte capacity.

Example: 12 × 600 MW. For multiple reactors capacities, use the <br/> function.

reactors_cancel_mwNumber of planned reactors cancelled, and former potential future gross megawatte capacity. Not to be confused with reactors_decom_mw below.

Example: 12 × 600 MW. For multiple reactors capacities, use the <br/> function.

reactor_typeThe type(s) of reactors currently in use, and its corresponding number of reactors. For multiple reactors types, you may use the <br/> function.

For power stations using a single type of reactor, enter any one of the following auto-expanding fields:

PWR=PWR, BWR=BWR, PHWR=PHWR, RBMK=RBMK, GCR=GCR, AGR=AGR, FBR=FBR, PBR=PBR, MSR=MSR, AHR=AHR.

reactor_supplierReactor supplier(s)
turbine_manu_nppManufacturers/suppliers of turbine(s) and/or boiler(s)
Solar Power Stations
solar_farm_typeThe type of solar technology in use. Enter any one of the following auto-expanding fields:

PV=Flat-panel PV, CPV=CPV, CSP=CSP

pv_unitsNumber of Flat-panel PV units.
cpv_unitsNumber of CPV units.
cpv_concentrationConcentration of CPV plant: Low, Medium, or High. Поврзано: Types of CPV.
csp_technologyThe CSP technology in use. Enter any one of the following auto-expanding fields:

D=Dish Stirling, T=Solar power tower, F=Fresnel reflector, or P=parabolic trough.

csp_unitsNumber of CSP units in use.
heliostatsNumber of heliostats.
thermal_power_solarMWt capacity.
cpvtIs the power station a CPVT type? Add Yes or No.
turbine_manu_cspManufacturers/suppliers of turbine(s)
land_areaLand area used for entire facility. Consider using: {{Convert|XX|km2|mi2|0|abbr=on}}
Tidal Power Stations
tidal_technologyThe tidal technology in use. Enter any one of the following auto-expanding fields. For tidal barrage technology, please use infobox dam.

TSG=Tidal stream generator, DTP=Dynamic tidal power

tsg_typeType of tidal stream generator.
tsg_turbines_mwNumber of tidal stream generators and its corresponding gross megawatt capacity.

Example: 10 × 250 MW. For multiple generator capacities, use the <br/> function.

dtp_turbines_mwNumber of generators (turbines) of the dynamic tidal power structure, and its corresponding gross megawatt capacity.

Example: 10 × 250 MW. For multiple generator capacities, use the <br/> function.

turbine_manu_tideManufacturers/suppliers of turbine(s)
dtp_perp_lengthPerpendicular length of the dynamic tidal power structure.
dtp_para_lengthParallel length of the dynamic tidal power structure.
tidal_rangeTidal range created by the dynamic tidal power structure.
Wave Farms
wave_technologyThe wave technology in use (capture method). Capture methods are buoy (point absorber), surface-following attenuator, terminator, oriented perpendicular to the direction of wave propagation, oscillating water column, underwater attenuator.
converter_typeType of converter, e.g. hydroelectric turbine, hydraulic ram, elastomeric hose pump, pump-to-shore, air turbine, linear electrical generator. There may be other type of converters.
wave_converter_manuManufacturers/suppliers of converter(s)
wave_turbines_mwNumber of wave energy converters and its corresponding gross megawatt capacity.

Example: 10 × 250 MW. For multiple generator capacities, use the <br/> function.

location_typeLocation of the converter, e.g. offshore, nearshore, shoreline (onshore)
offshore_area_waveSurface area used for entire facility. Consider using: {{Convert|XX|km2|mi2|0|abbr=on}}
offshore_depth_waveAverage water depth at the converter locations. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
offshore_distance_waveMinimum distance from shore of wave farms. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
Wind Farms
wind_turbinesNumber of wind turbines in the wind farm.
turbine_manuManufacturer of the wind turbines (e.g. Vestas, General Electric Wind Energy, etc).

For multiple manufacturers, use the <br/> function.

turbine_modelManufacturer's model code for wind turbines (e.g. V80, GE2.5XL, etc)

For multiple models, use the <br/> function.

hub_heightHeight of the wind turbine towers from base to hub. Consider using: {{Convert|XX|m|ft|0|abbr=on}}

If multiple types of turbines are in use, enter the maximum value.

rotor_diameterDiameter of wind turbine rotor. Consider using: {{Convert|XX|m|ft|0|abbr=on}}

If multiple types of turbines are in use, enter the maximum value.

rated_wind_speedRated wind speed of the wind turbine model. Consider using: {{Convert|XX|m/s|ft/s|1|abbr=on}}

If multiple types of turbines are in use, enter the minimum value.

wind_farm_typeType of wind farm (Onshore, Nearshore, Offshore). Поврзано Types of wind farms.
onshore_elevationAverage ground altitude (don't add hub height) for Onshore wind farms. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
onshore_land_useGround usage of Onshore wind farms (e.g. Farm land, desert, etc).
onshore_areaLand area used for entire facility. Consider using: {{Convert|XX|km2|mi2|0|abbr=on}}
offshore_areaSurface area used for entire facility. Consider using: {{Convert|XX|km2|mi2|0|abbr=on}}
offshore_depthAverage water depth of Offshore wind farms. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
offshore_distanceMinimum distance from shore of Offshore wind farms. Consider using: {{Convert|XX|m|ft|0|abbr=on}}
All other typed of power stations
turbine_manuTurbine(s) and boiler(s) supplier(s)
primary_fuelPrimary fuel source
secondary_fuelSecondary fuel source (optional)
tertiary_fuelTertiary fuel source (optional)
generation_unitsNumber of generating units
turbine_manu_otherManufacturers/suppliers of turbine(s) and/or boiler(s)
thermal_power_allMWt capacity.
cogeneration_allIs the power station a cogeneration type? Add Yes or No.
combined_cycleIs the power station a combined cycle type? Add Yes or No.
ghg_emissionAverage annual greenhouse gas emissions.
Bottom section: For all infoboxes
installed_capacityCurrent gross installed capacity in megawatts. Ends automatically with "MW".
max_planned_capMaximum planned gross capacity (if further construction/development is pending) in megawatts. Ends automatically with "MW".
capacity_factorCapacity factor of the power station, in percentage.
average_annual_genAverage annual gross power generation of the previous whole year. Ends automatically with "GWh".
net_generationGross power generation since commissioning of the power station. Ends automatically with "GWh".
websiteOfficial website.
as_ofDate infobox facts last updated. Not for mere typo or text fixes; use this date to reflect the current power station facts.
extraUse this field to add an additional infobox within this infobox. Example.

Поврзано

  • {{Инфокутија Брана}}
  • {{Инфокутиај Далновод}}